AD80.35-S-6003-07A | DAS control lead, testing IMM electrical system |
| Scope of test | Tester/test connection | Operation/ requirement | Specified value | Possible cause/ remedy | ||
1.0 | Control line Drive authorization system + (PWM only) |
|
| A25.1 5 | Ignition: ON Sockets of DAS and PEC control modules disconnected | < 1 V | Wiring X98 Value in order: 1.1 |
1.1 | Control line Drive authorization system - (PWM only) |
|
| A25.1 5 | Ignition: OFF Sockets of DAS and PEC control modules disconnected | > 20 kΩ | Wiring X98 Value in order 1.2 |
1.2 | Control line Drive authorization system -//- (PWM only) | A13.2 12 |
| A25.1 5 | Ignition: OFF Sockets of DAS and PEC control modules disconnected | < 1 Ω | Wiring X98 PEC or WSP/DAS control module (read PEC fault memory with HHT) |