AD80.35-S-6002-02A | RFL test of electrical system control module antenna reception |
| Scope of test | Measuring instrument/ | Operation/Requirement | Specified value | Possible cause/remedy | ||
1.0 | RFL control module antenna Radio message receive (CAN only) |
| Ignition: ON Operate transmitter key |
for short time | 1.1 Transmitter key battery Antenna position Transmitter key activation status (activated or deactivated) Transmitter key or RFL control module | ||
1.1 | RFL control module antenna + (CAN and PWM) |
|
| A25.1 1 | Ignition: OFF Coupling on RFL control module disconnected | <1 V | Cable Value O.K.: 1.2 |
1.2 | RFL control module antenna – (CAN and PWM) |
|
| A25.1 1 | Ignition: OFF Coupling on RFL control module disconnected | >20 kΩ | Cable Transmitter key or RFL control module Value O.K.: Transmitter key battery Antenna position Transmitter key activation status (activated or deactivated) |