ad8035p600012a

Actuation of relay/combination relay module, short-circuit to ground, testing electrical system (RFL/RCL)

Type ad · emne 80.35 · version 0101 · 2003-06-13

Gælder for: MODEL 129, 140 as of 1.6.97, 168, 170 as of 1.6.97 MODEL 170 with CODE (491) USA version with CODE (498) Japanese version

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 80 Centrallåsesystem, komfortbetjening, kørselsgodkendelsessystemer › 80.35 Radiofjernbetjening — Serie 129 · Serie 140 · Serie 168 · Serie 170

EinPAS 29 kørselsgodkendelses-/sikringssystem › 29.16 Aflåsning/oplåsning › 29.16.1 Grundinformation — Serie 129 · Serie 140 · Serie 168 · Serie 170

AD80.35-P-6000-12A

Actuation of relay/combination relay module, short-circuit to ground, testing electrical system (RFL/RCL)

Scope of test

Measuring instrument/
Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Actuation of lock confirmation relay (K54) or combination relay module (N10/2)

Cable

–

16

(1.2)

N54/3

N54/4

30

(1.16)

Disconnect N54/3 or N54/4 from .

Disconnect K54 or N10/2.

>20 kΩ

Cable