ad8035p600012a
Actuation of relay/combination relay module, short-circuit to ground, testing
electrical system (RFL/RCL)
Type ad · emne 80.35 · version 0101 · 2003-06-13
Gælder for: MODEL 129, 140 as of 1.6.97, 168, 170 as of 1.6.97 MODEL 170 with CODE (491) USA version with CODE (498) Japanese version
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 3 Karrosseri › 80 Centrallåsesystem, komfortbetjening, kørselsgodkendelsessystemer › 80.35 Radiofjernbetjening — Serie 129 · Serie 140 · Serie 168 · Serie 170
EinPAS 29 kørselsgodkendelses-/sikringssystem › 29.16 Aflåsning/oplåsning › 29.16.1 Grundinformation — Serie 129 · Serie 140 · Serie 168 · Serie 170
AD80.35-P-6000-12A
| Actuation of relay/combination relay module, short-circuit to ground, testing electrical system (RFL/RCL)
|
|
|
| Scope of test
| Measuring instrument/ Test connection
| Operation/Requirement
| Specified value
| Possible cause/Remedy
|
|
|
|
|
|
|
|
|
|
1.0
| Actuation of lock confirmation relay (K54) or combination relay module (N10/2)
Cable
–
|
16
(1.2)
| N54/3
N54/4
|
30
(1.16)
| Disconnect N54/3 or N54/4 from .
Disconnect K54 or N10/2.
| >20 kΩ
| Cable
|