AD80.35-D-6002-07B

RFL test of electrical system immobilizer malfunction indicator lamp

Engine 601, 602

Scope of test

Tester/test connection

Operation/

Requirement

Specified value

Possible cause/

Remedy

1.0

Immobilizer indicator lamp

Actuation

(CAN)

Ignition: ON

Immobilizer indicator lamp

ON

OFF

ON

OFF

Wiring

Indicator lamp

Instrument cluster

Specification OK:

Erase fault memory and perform operational check

1.1

-//-

(CAN)

A25.1

4

Ignition: OFF

Socket disconnected at RFL control module

(Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.)

<25 Ω

Wiring

Indicator lamp

Instrument cluster

1.2

-

(CAN)

A25.1

4

Ignition: OFF

Socket at RFL control module

and connector 2 (white) at instrument cluster disconnected

(Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.)

>20 kΩ

Wiring

1.3

+

(CAN)

A25.1

4

Socket at RFL control module

and connector 2 (white) at instrument cluster disconnected

(Engine OM 601 and OM 602 with DFI control module, additionally unplug connector 1 at preglow time relay.)

(Engine OM 602 with DFI control module, additionally remove relay K45)

Ignition: ON

<1 V

Wiring

Further possibilities:

RFL control module