AD80.20-D-6001-31A | CL test of electrical system left sliding door command switch |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Operation of command switch Left sliding door | 8 | | 10 | Connector unplugged from control module A8 Left sliding door closed Unlock left sliding door Lock left sliding door measured at connector of control module |
5 Ω 5 Ω | Wiring Command switch Rotary tumbler switch |
1.1 | Operation of command switch | 15 | | 10 | Unlock left sliding door Lock left sliding door measured at connector of control module |
> 5 Ω 5 Ω | Wiring Command switch Rotary tumbler switch |