ad5430d600017a

IC test of electrical system preglow and immobilizer indicator lamp

Type ad · emne 54.30 · version 0100 · 2003-06-10

Gælder for: MODEL 901, 902, 903, 904

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 54 El-system, udrustning og instrumenter › 54.30 Kombi-instrument, indikatorinstrumenter, advarselsanordninger — Serie 901 · Serie 902 · Serie 903 · Serie 904

EinPAS 31 Kommunikation/information/underholdning › 31.30 Kombiinstrument/køretøjscomputer › 31.30.1 Grundinformation — Serie 901 · Serie 902 · Serie 903 · Serie 904

AD54.30-D-6000-17A

IC test of electrical system preglow and immobilizer indicator lamp

Scope of test

Measuring instrument/Test connection

Operation/

Requirement

Specified value

Possible cause/

Remedy

1.0

Preglow and immobilizer (DAS)

malfunction indicator lamp

Cable and instrument cluster

3

1

Coupling disconnected at preglow time-limit relay

Coupling disconnected at radio remote operation control module

Ignition: ON

Malfunction indicator lamp illuminates

Cable

Malfunction indicator lamp

Instrument cluster

If in order:

Preglow time-limit relay or radio remote operation control module

1.1

Function

19

(2.1)

3

(1.5)

Instrument cluster removed

Adapter connected with adapter cable

Bridge to adapter cable

Malfunction indicator lamp illuminates

Malfunction indicator lamp

Instrument cluster