ad0761p600215a
Alarm equipment, ME-SFI idle speed control/electronic accelerator electrical
testing
Type ad · emne 07.61 · version 0102 · 2003-06-10
Gælder for: ENGINE 120 except CODE (494a) USA version except CODE (498) Japanese version
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME
EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation
Gælder også for motorer/gearkasser: 120 ***
AD07.61-P-6002-15A
| Alarm equipment, ME-SFI idle speed control/electronic accelerator electrical testing
| except ,
|
|
| Test of
| Tester/test connection
| Operation/
Requirement
| Specified value
| Possible cause/
Remedy
|
|
|
|
|
|
|
|
|
|
1.0
| Alarm equipment for 30 km/h restriction
Actuation
except
right ME-SFI control module only (N3/12)
|
26
(1.26)
| N3/12
|
47
(1.47)
| Ignition: ON
| Alarm must sound
| Cable
Instrument cluster
|