AD07.61-P-6002-13A | Refrigeration compressor signal, ME-SFI idle speed control/electronic accelerator electrical testing | up to 5/96 |
| Test of | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | A/C compressor signal up to 5/96 Right ME-SFI control module only (N3/12) |
38 (1.38) | N3/12 |
8 (1.8) | Engine: Idle speed Air conditioning: Switch on, temperature control wheels to minimum, switch blower on. | < 1.0 V 11 - 14 V | Cable Air conditioning pushbutton control module |