ad0761p600210a

Front speed signal, ME-SFI idle speed control/electronic accelerator electrical testing

Type ad · emne 07.61 · version 0102 · 2003-06-10

Gælder for: ENGINE 120 up to 31.5.98

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-6002-10A

Front speed signal, ME-SFI idle speed control/electronic accelerator electrical testing

up to 5/98

Test of

Tester/test connection

Operation/

Requirement

Specified value

Possible cause/

Remedy

1.0

Front left speed signal

up to 5/98

Right ME-SFI control module only (N3/12)

38

(1.38)

N3/12

9

(1.9)

Raise vehicle at front.

Ignition: ON

Rotate front left wheel by hand.

4 - 8 V

Cable

AD42.45-P-1001AZ