AD07.61-P-6001-01B | ME-SFI control module terminal 30 - ME-SFI ignition system - Testing electrics |
| Scope of test | Tester/test connection | Operation/ Prerequisite: | Specified value | Possible cause/ Remedy | ||
1.0 | ME-SFI control module (N3/10) Voltage supply terminal 30 |
3 (3A) | N3/10 |
12 (4B) | Ignition: ON | 11-14 V | 1.1 1.2 |
1.1 | Ground cables | N3/10 3 (3A) 7 (7A) 112 (8F) 119 (15F) |
|
X11/4 2 X11/4 2 X11/4 2 X11/4 2 | Ignition: ON | 11-14 V | Cable Models 208/210: Electronics ground component compartment (W16/6) Model 163: Electronics ground component compartment (W16) Model 129: Module box bracket ground (W27) Model 463: Right A-pillar ground (W29/2), control module box bracket ground (W27) |
1.2 | Voltage supply terminal 30 |
X11/4 1 |
|