ad0761p600043a

Oxygen sensor heater upstream TWC - Check ME-SFI gasoline injection electrics

Type ad · emne 07.61 · version 0103 · 2003-06-10

Gælder for: ENGINE 104.941 /943 /944 /991 /994 as of 1.8.96 ENGINE 104.995 with CODE (494a) USA version with CODE (807) Model year 1997 with CODE (808) Model year 1998 with CODE (498) as of Model Year 97 Japanese version ENGINE 111.921 /942 as of 1.9.98, 111.943, 111.944 as of 1.8.96, 111.946 as of 1.6.98, 111.947 /973, 111.975 as of 1.8.96 ENGINE 111.945 in MODEL 208.335 /435 as of 1.6.98, 202.020 /080 as of 1.9.98 ENGINE 111.974 with CODE (494a) USA version with CODE (807) Model year 1997 with CODE (80

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME — Serie 202 (modeller 020, 080) · Serie 208 (modeller 335, 435)

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation — Serie 202 (modeller 020, 080) · Serie 208 (modeller 335, 435)

Gælder også for motorer/gearkasser: 104 941, 104 943, 104 944, 104 991, 104 994, 104 995, 111 921, 111 942, 111 943, 111 944, 111 945, 111 946, 111 947, 111 973, 111 974, 111 975

AD07.61-P-6000-43A

Oxygen sensor heater upstream TWC - Check ME-SFI gasoline injection electrics

Scope of test

Tester/test connection

Operation/

prerequisite:

Specified value

Possible cause/

remedy

1.0

Oxygen sensor upstream TWC (G3/2)

Oxygen sensor heater

Actuation

Power consumption G3/2

5

(5A)

3

(3A)

N3/10

N3/10

2

(2A)

5

(5A)

At coolant temperature

> 80 °C allow engine to run for approx.

2 minutes at idle speed

Ignition: ON

11 - 14 V

0.6 - 3.4 A

Lead

G3/2

ME-SFI control
module (N3/10)