AD07.61-P-6000-02A | Testing of electrical system for ME-SFI control module terminal 87 in ME-SFI fuel injection system |
| Scope of test | Tester/test connection | Operation/ Prerequisite: | Specified value | Possible cause/ Remedy | ||
1.0 | ME-SFI control module (N3/10) Terminal 87 voltage supply |
8 (8A) |
N3/10 |
2 (2A) | Ignition: ON | 11-14 V | 1.1 1.2 |
1.1 | Ground electronics |
N3/10 8 (8A) |
|
X11/4 2 | Ignition: ON | 11-14 V | Cable Models 202/208/210: Electronics ground, right of component compartment (W16/6) Model 129: Ground (control module box/module box bracket) (W27) Model 163: Ground (component compartment) (W16) Model 463: Ground (right A pillar) (W29/2) |
1.2 | Terminal 87 voltage supply |
X11/4 1 |
|
N3/10 2 (2A) | Ignition: ON On model 163, connect to 16-pin test coupling, socket 4. Ignition: OFF | 11-14 V < 1 V | Cable Fuse and relay module, base module (K40, K40/4, F1 or N16/1) |