ad0761p400059b

Control module voltage supply, ME-SFI fault code description

Type ad · emne 07.61 · version 0100 · 2003-06-10

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-59B

Control module voltage supply, ME-SFI fault code description

1

Fault code

for right cylinder bank

for left cylinder bank

2

Fault memory and actuation of CHECK ENGINE malfunction indicator lamp (MIL)

After two consecutive driving cycles with fault

3

Frequency of test

Continuous

4

Tested signal or condition

Battery voltage

5

Lower limit value

Upper limit value

Test duration

Approx. 8 V and 17.5 V

Approx. 17.5 V

< 5 s

6

Test conditions

Waiting time of approx. 180 s after start expired