ad0761p400055b

Fault code description when one intake valve of a cylinder is not actuated with cylinder cut-out system OFF, ME-SFI

Type ad · emne 07.61 · version 0101 · 2003-06-10

Gælder for: ENGINE 113.960 up to 31.5.00 with CODE (479) Cylinder shutoff

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.17 Motorstyring › 15.17.1 Grundinformation

Gælder også for motorer/gearkasser: 113 960

AD07.61-P-4000-55B

Fault code description when one intake valve of a cylinder is not actuated with cylinder cut-out system OFF, ME-SFI

Engine 113.960 up to 5/00 with code (479) cylinder cut-out system

1

Fault code

2

Fault storage

Activation of malfunction indicator lamp for engine diagnosis

after the end of the test period and faults

no activation of the malfunction indicator lamp

3

Frequency of the test

Monitoring period

continuous

approx. 5 s

4

Fault setting conditions

Combustion misfire (detection via smooth operation assessment) detected in the upper load and speed range

5

Test prerequisites

- engine speed approx. 5000 rpm

- load > approx. 80%

- no fault in hot film mass air flow sensor, crankshaft position sensor, pressure sensor (intake manifold)

- no fault at cylinder cut-out system valves (Y80, Y81)

6

- If, due to a defective rocker arm coupling (rocker arm, coupling pin), only one intake valve of a cylinder is actuated, this leads to misfires in the upper load and speed range.

- The fault code output only serves as additional service information, since with this test, the cause cannot be definitively assigned to the cylinder cut-out system.

- If this fault occurs, the engine diagnosis malfunction indicator lamp is activated immediately due to the simultaneously active fault identification for a misfire "damaging to TWC".