ad0761p400042b

ME-SFI fault code description secondary air injection

Type ad · emne 07.61 · version 0100 · 2003-06-10

Gælder for: ENGINE 120 with CODE (620a) Fahrzeuge mit Katalysatortechnik

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-42B

ME-SFI fault code description secondary air injection

with CODE (620a) vehicles with three way catalytic convertor (TWC) technology

1

Fault code

AIR pump switchover valve (Y32)

AIR relay module (K17)

2

Fault memory and actuation of CHECK ENGINE (MIL)

After two consecutive journeys with fault

3

Frequency of testing

Continuous

4

Checked signal or status

The voltage supply of the air pump in AIR relay module and AIR pump switchover valve (Y32) is evaluated via a current measurement in the respective output stage.

5

Lower limit value

Upper limit value

approx. 3 V

approx. 9 V

6

Test conditions

Secondary air injection active