ME-SFI secondary air injection - Fault code description
Type ad · emne 07.61 · version 0104 · 2003-06-10
Gælder for: ENGINE 112.910, 112.911 up to 31.5.00, 112.920, 112.921 up to 31.5.00, 112.923, 112.940 /941 /942 up to 31.5.00, 112.943 ENGINE 113.940 /942 /943 up to 31.5.00, 113.961 ENGINE 112.945, 113.962 up to 30.11.00 in MODEL 463
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME — Serie 463
EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation — Serie 463
ME-SFI secondary air injection - Fault code description
1
Fault code
Air pump changeover valve (Y32)
Air pump relay in the fuse and relay module
2
Fault storage
Activation of the engine diagnosis (EURO3/4)
or CHECK ENGINE (MIL) malfunction indicator lamp
Following the expiry of the test duration and fault
Following two consecutive driving cycles with fault
3
Frequency of the test
Continuously
4
Checked signal or status
The voltage supply of the air pump relay in the fuse and relay module and the air pump changeover valve (Y32) are evaluated by measuring the current in the relevant output stage.
5
Fault setting conditions
Limit values
Secondary air injection OFF: A maximum of 3 V may be present at the output
Secondary air injection ON: At least 9 V must be present at the output