Activation of malfunction indicator lamp for engine diagnosis (EURO3/4)
or CHECK ENGINE (MIL)
after the end of the test period and faults
after two successive driving cycles with faults
3
Frequency of the test
continuous
4
Checked signal or status
Duty cycle for PWM-solenoid activation
5
Fault setting conditions
Lower limit
Upper limit
Test duration
Duty cycle less than 5 %
Duty cycle greater than 94 %
approx. 1 s
6
Faults (line interruption and short circuit) are detected by the ETC control module and sent via the CAN data bus to the ME-SFI control module. The faults are stored and the malfunction indicator lamp is activated by the ME-SFI control module.
Also read out ETC diagnostic trouble code memory, fault code 5.