ad0761p400031b

ME-SFI fault code description supply voltage and operation of speed sensors

Type ad · emne 07.61 · version 0100 · 2003-06-06

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-31B

ME-SFI fault code description supply voltage and operation of speed sensors

1

Fault code

2

Fault memory and actuation of CHECK ENGINE (MIL)

After two consecutive journeys with fault

3

Monitoring time and frequency of testing

Continuous

4

Checked signal or status

– Supply voltage, speed sensors

– Speed signal n2

– Speed signal n3

5

Supply voltage, speed sensors

Lower limit value

Upper limit value

Speed signals n2, n3

Duration of test

< 4.8 V

> 7.2 V

Signals recognized and plausible

< 1 s

6

Test conditions

Speed signal n2

Test conditions

Speed signal n3

– Engine speed > 450 rpm

– Rear right wheel speed > 250 rpm

– Rear left wheel speed > 250 rpm

– 3rd or 4th gear recognized

– Output shaft speed > 150 rpm (> 20 km/h)

– No shift process

7

Test sequence

The speed signals must be recognized as of a particular engine speed and wheel speed. 3rd and 4th gear must also be shifted for the speed signal n3.

8

Faults are recognized by the ETC control module and conveyed to the engine control module (ME-SFI) via the CAN data bus.

The engine control module (ME-SFI) carries out fault memory and actuation of CHECK ENGINE (MIL). Also read out the ETC fault memory, fault codes 11, 12, 13.