ad0761p400010c

ME-SFI fault code description fuel injectors

Type ad · emne 07.61 · version 0100 · 2003-06-06

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-10C

ME-SFI fault code description fuel injectors

1

Fault code

2

Fault memory and actuation of CHECK ENGINE (MIL)

After two consecutive journeys with fault

3

Frequency of testing

Continuous

4

Checked signal or status

Current/voltage testing on respective fuel injector

5

Limit value of current consumption

Limit value of voltage

Duration of test

> 4.2 A

< 2.5 V

< 5 s

6

The actuation of each fuel injector is tested for cable open-circuit and short-circuit (to ground or battery voltage).

In the event of a fault the output stage stops being actuated immediately.

7

In the event of a short-circuit to ground the corresponding fuel injector is opened permanently.