ad0761p400008aa

O2-sensor heating - fault code description ME-SFI

Type ad · emne 07.61 · version 0102 · 2005-08-17

Gælder for: ENGINE 112.910 /911 /920 /921 /922 /940 /941 /942 /944 as of 1.6.00 ENGINE 112.912 /913 /914 /916 /917 /923 /943 /946 /947 /949 /953 /954 /955 /970 /972 /973 /975 ENGINE 113.940 /941 /942 /943 /960 as of 1.6.00 ENGINE 113.948 /961 /963 /964 /965 /966 /967 /968 /969 /971 ENGINE 112.945, 113.962 as of 1.11.00 in MODEL 463

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME — Serie 463

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation — Serie 463

Gælder også for motorer/gearkasser: 112 910, 112 911, 112 912, 112 913, 112 914, 112 916, 112 917, 112 920, 112 921, 112 922, 112 923, 112 940, 112 941, 112 942, 112 943, 112 944, 112 945, 112 946, 112 947, 112 949, 112 953, 112 954, 112 955, 112 970, 112 972, 112 973, 112 975, 113 940, 113 941, 113 942, 113 943, 113 948, 113 960, 113 961, 113 962, 113 963, 113 964, 113 965, 113 966, 113 967, 113 968, 113 969, 113 971

AD07.61-P-4000-08AA

O2-sensor heating - fault code description ME-SFI

O2 sensor heater (G3/3 to G3/6), heat output is too low

1A

Fault code

( Readout on generic scan tool)

P2008 Right O2 sensor upstream of TWC (G3/4) (P0135)

P2009 Right O2 sensor downstream of TWC (G3/6) (P0141)

P2088 Left O2 sensor upstream of TWC (G3/3) (P0155)

P2089 Left O2 sensor downstream of TWC (G3/5) (P0161)

1B

Engines 112, 113 as of 1/01

Fault code

( Readout on generic scan tool)

P2008-[8] Right O2 sensor upstream of TWC (G3/4) (P0135)

P2009-[8] Right O2 sensor downstream of TWC (G3/6) (P0141)

P2088-[8] Left O2 sensor upstream of TWC (G3/3) (P0155)

P2089-[8] Left O2 sensor downstream of TWC (G3/5) (P0161)

2

Fault storage

Actuation of the engine diagnosis indicator lamp (EURO3/4) or

CHECK ENGINE (MIL)

after expiry of test duration and fault

following two successive driving cycles with faults

3

Checking frequency

Continuous

4

Checked signal or status

Internal resistance of the Nernst cells (generate the O2 sensor signal)

5

Fault setting conditions

O2 sensors upstream of TWC

O2 sensors downstream of TWC

OK if the calculated resistance value for a hot O2 sensor is 130 to 580 Ω (model 170: 130 to 480 Ω).

OK if the calculated resistance value for a hot O2 sensor is 160 to 1020 Ω (model 170: 160 to 770 Ω).

6

Check prerequisites

Exhaust and catalytic converter temperature 380 to 560°C

7

The internal resistance of Nernst cells is used as a criterion for the testing.

The internal resistance of Nernst cells must be within tolerance for the specified exhaust and catalytic converter temperature.

If a fault on voltage supply for O2 sensor heater is also stored then first check the voltage supply (connector, line, fuse).

In cases of a fault on the O2 sensor heater check:

1) Connector, line and fuse.

2) For a short circuit to ground: measure the resistor between the O2 sensor housing and the sensor heater (connection 1 or 2). Replace the O2 sensor if the resistance is less than 100 Ω.

3) For a short circuit to battery voltage: check the cold resistance (+25°C) of the sensor heater between connection 1 and 2. Replace the O2 sensor if the resistance is less than 4.5 Ω.

4) For line discontinuity: check the cold resistance (+25°C) of the sensor heater between connection 1 and 2. Replace the O2 sensor if the resistance is greater than 12 Ω.

Use of cleaning or greasing fluids (sprays) and evaporating greases on the O2 sensor or the screw-in thread is not permissible. The screw-in thread must only be lubricated using the released grease.

Broaching of the sensor lines is not permissible.

O2-sensor heating - fault code description ME-SFI

P07.61-2557-01

View of electrical connection for O2sensor

1 Sensor heating

2 Sensor heating ground

3 Ground O2 sensors signal

4 O2 sensor signal