ad0761p400006b

ME-SFI fault code description O2 sensor signal

Type ad · emne 07.61 · version 0100 · 2003-06-06

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-06B

ME-SFI fault code description O2 sensor signal

1

Fault code

right before TWC

right after TWC

right before TWC

left before TWC

left after TWC

left before TWC

2

Fault memory and actuation of CHECK ENGINE (MIL)

After two consecutive journeys with fault

3

Frequency of testing

Continuous

4

Checked signal or status

A Limit values of oxygen sensor signal

B Sensor status change

5

A Limit values of oxygen sensor signal

Lower limit value

Upper limit value

Duration of test

B Sensor status change

< -0.15 V

> 1.5 V

< 5 s

After approx. 220 seconds with the sensor heater switched on the sensor signal must not dwell in the 0.4 - 0.6 V voltage window for more than approx. 5 seconds.

6

Test conditions

– Engine speed approx. 1000-2000 rpm

– Load approx. 15-50 %

– Three way catalytic converter temperature > 300°C

– Lambda control enabled

7

All electrical connection faults of the oxygen sensors before TWC or after TWC (cable open-circuit and short-circuit to ground or battery voltage) are recognized by means of the tests.