AD07.52-D-6000-22A | PEC fuel injection and ignition system test of electrical system purge control valve |
| Scope of test | Measuring instrument/Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Purge control valve (Y1) Actuation | | Engine: Idling and operating temperature Purge actuation ON | Purge control valve switches audibly/ perceptibly | Cable 1.1 | ||
1.1 | Voltage | | Engine: Idling and operating temperature Purge actuation OFF Measured at control valve /control module coupling |
11 - 14 V | If specified value not achieved: Replace purge control valve | ||