AD07.51-S-6000-41B | CAN data bus, testing electrical system of fuel injection system (HFM-SFI) | For engine 104.900 in model 638.294 |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | CAN data bus (For engine 104.900 in model 638.294) |
41 (1.41) | A52.1 |
29 (1.29) | Ignition: OFF |
55 - 65 Ω | Data cable 1.1 1.2 |
1.1 | CAN module in DAS control unit Resistance (For engine 104.900 in model 638.294) |
41 (1.41) | A52.1 |
29 (1.29) | Ignition: OFF Connector A52.1 on control module (A52) disconnected |
115 - 125 Ω | DAS control module 1.2 |
1.2 | CAN module in control unit (A52) Resistance (For engine 104.900 in model 638.294) |
41 (1.41) | A52.1 |
29 (1.29) | Ignition: OFF Connector A52.1 disconnected from test cable |
115 - 125 Ω | Control module A52 1.3 |
1.3 | Cable -//- (For engine 104.900 in model 638.294) Cable - Cable + | A52.1 41 (1.41) 29 (1.29) |
|
A25 5 6 A52.1 41 (1.41) 29 (1.29) A52.1 41 (1.41) 29 (1.29) | Ignition: OFF Connector A52.1 on control module disconnected Connector on control module A25 disconnected Ignition: OFF Connector A52.1 on control module disconnected Connector on control module A25 disconnected Connector A52.1 on control module disconnected Connector on control module A25 disconnected Ignition: ON |
< 5 Ω < 5 Ω > 20 kΩ > 20 kΩ 2.5 V 2.5 V | Test cable for –//– Test cable for - Test cable for + |