sm8285p0042a

Program head unit (code: 1710P54C91)

Typ sm · téma 82.85 · verze 0100 · 2018-02-27

Platí pro: Model 205, 253 with code 531 (COMAND APS)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 82 Elektrické zařízení, nástavba › 82.85 Navigační a komunikační systémy — Řada 205 · Řada 253

EinPAS 31 Komunikace/informace/zábava › 31.10 Hlavní jednotka › 31.10.11 Řídicí jednotka/relé — Řada 205 · Řada 253

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.40 Servisní opatření — Řada 205 · Řada 253

SM82.85-P-0042A

Program head unit (code: 1710P54C91)

22.02.2018

Model

205, 253

with code 531 (COMAND APS)

Operation no. of the operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

P

02-4762

Connect/disconnect vehicle diagnosis system (XENTRY Diagnosis)

P

02-5058

Connect/disconnect starter battery charger (XENTRY Diagnosis connected)

P

02-9334

Update control unit software ............. (XENTRY Diagnosis connected) Acc. no.: .... ....., code: .... .............

Check

1

Check whether vehicle is affected by measure.


Model 205 as of 262821 up to 675880 with code 531

SM82.85-P-0042-01AAA

Model 253 as of 203332 up to 379612 with code 531

SM82.85-P-0042-01AAB

Programming

2

Connect diagnostic unit.

Use XENTRY Diagnostics version 09/2017 or higher with all available addons. The operation steps must be performed exactly as per XENTRY Diagnostics! Make sure that the vehicle's on-board electrical system battery has sufficient power (more than 12.5 V) by using a battery charger. If XENTRY Diagnostics is already connected to the vehicle, continue with operation step 3.

AD00.00-P-2000-04B

3

Program head unit (A26/17).

To do so, select menu item Control units view  Information and communication  Audio or COMAND  Adaptations  Update control units  Update control unit software.

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

4

Disconnect diagnostic unit.

AD00.00-P-2000-04B

Odkazované dokumenty