sm4245p0028a

Program Electronic Stability Program (ESP(R)) control unit (code: 1806P42B65)

Typ sm · téma 42.45 · verze 0100 · 2019-01-02

Platí pro: Model 205

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 42 Brzdy - hydraulická část a mechanická část › 42.45 Elektronický stabilizační systém (ESP), regulace stability (SR) — Řada 205

EinPAS 26 Systémy aktivní bezpečnosti › 26.20 Regulace brzd/ trakce › 26.20.11 Řídicí jednotka/relé — Řada 205

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.40 Servisní opatření — Řada 205

SM42.45-P-0028A

Program Electronic Stability Program (ESP(R)) control unit (code: 1806P42B65)

07.12.2018

Model

205

Operation no. of the operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

P

02-4762

Connect/disconnect vehicle diagnosis system (XENTRY Diagnosis)

P

02-5058

Connect/disconnect starter battery charger (XENTRY Diagnosis connected)

P

02-9334

Update control unit software ............. (XENTRY Diagnosis connected) Acc. no.: .... ....., code: .... .............

Check

1

Check, whether the vehicle is affected by the measure.


Model 205 as of 670605 up to 725627

SM42.45-P-0028-01AAA

Programming

2

Connect diagnostic unit.

Use XENTRY Diagnostics version 09/2018 or higher with all available add-ons. The operation steps must be performed exactly as per XENTRY Diagnostics! Make sure that the vehicle's on-board electrical system battery has sufficient voltage supply (more than 12.5 V) by using a battery charger. If XENTRY Diagnostics is already connected to the vehicle, continue with operation step 3.

AD00.00-P-2000-04B

3

Program Electronic Stability Program control unit (N30/4).

To do so, select menu item Quick test view  N30/4 Electronic Stability Program (ESP)  Adaptations  Control units update  Update of control unit software.

Then follow the user guidance in XENTRY Diagnostics.

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

4

Disconnect diagnostic unit.

AD00.00-P-2000-04B

Odkazované dokumenty