sm4245p0019a

Program Electronic Stability Program (ESP(R)) control unit (code: 1601P43A03)

Typ sm · téma 42.45 · verze 0101 · 2018-07-10

Platí pro: Model 205

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 42 Brzdy - hydraulická část a mechanická část › 42.45 Elektronický stabilizační systém (ESP), regulace stability (SR) — Řada 205

EinPAS 26 Systémy aktivní bezpečnosti › 26.20 Regulace brzd/ trakce › 26.20.11 Řídicí jednotka/relé — Řada 205

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.40 Servisní opatření — Řada 205

SM42.45-P-0019A

Program Electronic Stability Program (ESP(R)) control unit (code: 1601P43A03)

09.07.2018

Model

205

Operation no. of the operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

P

02-4762

Connect/disconnect diagnostic system (Xentry/DAS)

P

02-5058

Connect/disconnect battery charger (with Xentry/DAS connected)

P

02-9334

Update control unit ......................... software (with XENTRY/DAS connected), Acc. no.: .........., code: ..........

Check

1

Check whether vehicle is affected by measure


Model 205 as of 089868 up to 308640

SM42.45-P-0019-01AAA

Programming

2

Connect diagnostic unit

Use XENTRY Diagnostics version 12/2015 with all available add-ons or a newer version. The operation steps must be performed exactly as per Xentry Diagnostics! Make sure that the vehicle's on-board electrical system battery has sufficient voltage supply (more than 12.5 V) by using a battery charger. If Xentry Diagnostics is already connected to the vehicle, continue with operation step 3.

AD00.00-P-2000-04B

3

Program Electronic Stability Program control unit (N30/4)

To do so, select menu item Control units view  Suspension  ESP® Electronic Stability Program  Adaptations  Control units update  Update of control unit software.

Then follow the user guidance in Xentry Diagnostics.

If two or more instances of control unit programming or SCN coding are carried out during a workshop visit, the operation items 02­4762 and 02­5058 must only be charged once for each workshop order.

5

Disconnect diagnostic equipment

AD00.00-P-2000-04B

Odkazované dokumenty