sm0715w0015d

Update software release in engine management control unit (MCM)

Typ sm · téma 07.15 · verze 0100 · 2020-03-25

Platí pro: Engine 470.9, 471.9, 473.9 in model 963, 964 Code: MCM-V

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.15 Systém vstřikování paliva vznětového motoru (PLD), regulace motoru (MR) — Řada 470 (modely 9**) · Řada 471 (modely 9**) · Řada 963 · Řada 964

EinPAS 15 Motor › 15.45 Management motoru › 15.45.11 Řídicí jednotka/relé — Řada 470 (modely 9**) · Řada 471 (modely 9**) · Řada 963 · Řada 964

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.40 Servisní opatření — Řada 470 (modely 9**) · Řada 471 (modely 9**) · Řada 963 · Řada 964

Platí také pro motory/převodovky: 473 9**

SM07.15-W-0015D

Update software release in engine management control unit (MCM)

23.03.2020

Engine

470.9, 471.9, 473.9 in model 963, 964

Code: MCM-V

Operation no. of the operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

N

541011

Perform quick test

0,3 h

-

-

N

540650

Maintain on-board electrical system voltage (for testing and diagnosis work)

0,1 h

-

-

N

541022

Create output report (with XENTRY/DAS connected)

0,1 h

-

-

N

021795

Update software release in engine management control unit (MCM) (XENTRY Diagnosis connected).

0,1 h

07 975 60

MCM-V

Update software release

1

Connect diagnostic system, start XENTRY and switch on ignition.

The update requires that at least XENTRY update 12/2019 is installed.
If several control units are programmed, parameters are changed or other operations are performed with XENTRY during a workshop visit, operation items 54­1011, 54­0650 and 54-1022 may only be invoiced once!

2

Perform initial quick test.

The initial quick test is stored until the end of the diagnosis session.

3

Update software release in engine management control unit (MCM).

The update procedure is completely menu-assisted under:
MCM - engine management (A4)  
Adaptations 
Initial startup 
Control module programming

4

Perform final quick test.

There must be no fault codes in the control units being updated.

If fault codes are still present in control units being updated,

then process the fault codes.

After obtaining special order.

5

End XENTRY and remove the diagnostic system.