SI62.20-P-0006A | Service Information: Replace end plate | 28.2.07 |
MODEL 210.0 /2 (except 210.08 /28)
except CODE (979) Special protection version
except CODE (Z04) Light armoring
except CODE (Z06) B6 armoring
Operation no. of operation texts or standard texts and flat rates
Category | Op. no. | Operation text |
PPP | 025617 | Replace end plate with spring mount on left front longitudinal member |
PPP | 025623 | Replace end plate with spring mount on right front longitudinal member |
PPP | 025622 | Extra work for: replace end plate with spring mount on front longitudinal member, location:..... end plate, large version |
There is an additional repair method for repairing the end plate on the front longitudinal member. In other words two repair methods (I, II) are available for the end plate. The repair method with unperforated end plate should only be used in the exceptional case (with severely advanced corrosion and rust-through damage in the upper/front area, see AR62.10-P-0009EB).
ok For the new repair methods using a perforated end plate the new operation items 02-5617, 02-5623 are available for the ASRA-run 03/2007 and are assigned flat rates.
-----------------------------------------------------------------------------------------
II. As of the ASRA run 05/2007 only new operation items 02-5617, 025623 and in addition the additional operation 02-5622 can be used for the existing repair method with unperforated end plate.
In ASRA run transition phase 03/2007 to 05/2007 the operation items 02-4196, 02-4197 used previously continue to be available.
-----------------------------------------------------------------------------------------
Replacement part ordering note:
The replacement part for end plates has been changed and is available with immediate effect
The replacement part are also available with code 05; do not start any EKOS-inquiry for these spare parts as the booking block simply causes the note "C87-Part not available to appear".
The replacement part is available via the usual ordering process.
Specialist information:
The valid repair instructions are available in the WIS update 03/2007 and contained in advance in this SI.