si5421w0020a

Service Information: Base module

Typ si · téma 54.21 · verze 0100 · 2006-07-25

Platí pro: MODEL 930, 932, 933, 934 with base module (A7) part no. A 000 446 00 58 up to A 000 446 13 58 in connection with flashware (FW) no. 000 448 11 58 to 000 448 16 58

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.21 Řídicí jednotky / moduly — Řada 930 · Řada 932 · Řada 933 · Řada 934

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.15 Síť/multifunkční systém › 25.15.11 Řídicí jednotka/modul/relé — Řada 930 · Řada 932 · Řada 933 · Řada 934

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.20 Servisní informace — Řada 930 · Řada 932 · Řada 933 · Řada 934

SI54.21-W-0020A

Service Information: Base module

27.5.04

MODEL 930, 932, 933, 934
with base module (A7) part no. A 000 446 00 58 up to A 000 446 13 58 in connection with flashware (FW) no.
000 448 11 58 to 000 448 16 58

The data of the base module (A7), part no. and flashware (FW) no. can be read out of the quick test or out of the control unit version in base module with STAR DIAGNOSIS.

The following complaints can occur on the above mentioned base modules in connection with the cited flashware (FW) no.:

1. During auxiliary heater operation

Ashtray illumination briefly brightens.

Cigarette lighter illumination briefly brightens.

Temporary undefined actuation of the function pin
(e.g. additional headlamps).

2. On vehicles with Code (FZ8) anti-theft alarm system (ATA [EDW]) without interior protection

Locking vehicle with remote several times leads to triggering of the alarm.

3. On vehicles with Code (EX3) FleetBoard telematic platform or with Code (EV0) communications interface (KOM)

Faulty overrun mode data in the FleetBoard evaluation.

Trailer ID cannot be read out through FleetBoard.

If one of these complaints occurs or if it is necessary to deactivate the fault recognition for the illumination of the trailer/semitrailer, the software (SW) of the base module (A7) must be changed. To do this you must have the STAR DIAGNOSIS CD as of 05/2004 and the SDflash release CD as of 05/2004. These are both delivered simultaneous.

Cost settlements are to be made using the damage code 53587ED. Only those control units within the above mentioned range may be programmed.

Operation no. of operation texts or standard texts and flat rates

Category

Op. no.

Operation text

Time

Acc. no.

Code

N

024863

OPERATION: UPDATE SOFTWARE OF BASE MODULE

015 WU

53 587 ED

---

Check/change software (SW) of base module (A7)

1

Connect STAR DIAGNOSIS

*WH58.30-Z-1049-13A

2

Perform quick test

3

Check data of base module (A7)

Only program the base module (A7) if its data are within the following range:

Base module (A7) part no. A 000 446 00 58 up to A 000 446 13 58 in connection with flashware (FW) nos. 000 448 11 58 to
000 448 16 58

If the data are not within the range:

End procedure.

If the data are within the range:

Proceed with step 4.

4

In the control unit GM (base module) menu, select "Control unit programming (SDflash)"

5

Follow the instructions

Programming the base module is menu assisted.

Commercially available tools

Number

Designation

WH58.30-Z-1049-13A

STAR DIAGNOSIS Compact diagnostic system for commercial vehicles

651 131 10 00