si4000w0001a

Service information: Rotation chains

Typ si · téma 40.00 · verze 0200 · 2004-02-03

Platí pro: MODEL 930, 932, 933, 934, 944, 950, 952, 953, 954 with retrofitted rotation chains (centrifugal snow chains)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 40 Kola, měření geometrie podvozku › 40.00 Všeobecné — Řada 930 · Řada 932 · Řada 933 · Řada 934 · Řada 944 · Řada 950 · Řada 952 · Řada 953 · Řada 954

EinPAS 26 Systémy aktivní bezpečnosti › 26.15 Pomoc při rozjezdu › 26.15.40 Rotační řetěz — Řada 930 · Řada 932 · Řada 933 · Řada 934 · Řada 944 · Řada 950 · Řada 952 · Řada 953 · Řada 954

EinPAS 45 Data/informace › 45.20 Informace/opatření › 45.20.20 Servisní informace — Řada 930 · Řada 932 · Řada 933 · Řada 934 · Řada 944 · Řada 950 · Řada 952 · Řada 953 · Řada 954

SI40.00-W-0001A

Service information: Rotation chains

26.8.02

MODEL 930, 932, 933, 934, 944, 950, 952, 953, 954
with retrofitted rotation chains (centrifugal snow chains)

Modification notes

28.1.04

Contents completely revised.

Within the scope of our production monitoring, we have noticed that electrostatic charging can result in fault messages and partial failure in the vehicle electronics under unfavorable circumstances during operation on vehicles retrofitted with rotation chains.

Models 944, 950, 952, 953, 954

A shop-made ground cable (1) with a cross-section of at least 6 mm2 must be installed between the rear axle housing (2) and clamp connector for circuit 31 (X9) when installing rotation chains.

The clamp connector for circuit 31 (X9) is located on the inside of the frame behind the battery box.

MODEL 930, 932, 933, 934

A shop-made ground cable (1) with a cross-section of at least 6 mm2 must be installed between the rear axle housing (2) and the power distributor when installing rotation chains.

To do so, an additional negative power distributor must be attached to the existing negative power distributor.

In addition, it is necessary to ensure that on all vehicles when the rotation chains are switched off, the gap (a) between the rotation chains and the road surface is at least 50 mm.

On vehicles with rotation chains already installed, the ground cable should be retrofitted the next time the vehicle is in the workshop and the distance between the rotation chains and road surface checked.

- This information will also be included in the body/equipment mounting directives and assembly instructions for rotation chains.

Installation of the ground cable as well as the additional power distributor and gap check is subject to charge and must not be billed to warranty or goodwill.

Service information: Rotation chains

W40.00-1000-11

Ground cable on rear axle

1 Ground cable

2 Rear axle housing

Service information: Rotation chains

W40.00-1001-11

Clamp connector on model 944, 950, 952, 953, 954

1 Ground cable

X9 Circuit 31 terminal connector

Service information: Rotation chains

W40.00-1003-11

Gap, rotation chain to road surface

A 50 mm

Service information: Rotation chains

W40.00-1004-11

Negative power distributor

3 Negative power distributor

4 Additional power distributor

Parts ordering notes

Part no.

Designation

Quantity

A 930 546 11 40

Negative power distributor

1

A 930 546 19 40

Cap