ra07016028244x

8244 - Testing start of delivery using the digital tester (RIV method) Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

Typ ra · téma 07.12 · verze 9606 · 1996-02-06

Platí pro:

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.12 Vstřikovací systém vznětového motoru s řadovým čerpadlem a elektronickou regulací (EVE, EDC) — Řada 602 (modely 96*)

Platí také pro motory/převodovky: 603 96*, 603 970, 603 971

07.1-8244 Testing Start of Delivery with Digital Tester (RIV Method)

Operation no. of operation texts and work units or standard texts and flat rates: 07-8244 or 07-8245

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

Screw plug (arrow) on governor housing (2)

unscrew, tightening torque 30-35 Nm.

Testers (001, 017, 021)

connect.

Engine

run at idling speed, read off RI value, adjust start of delivery if necessary (07-8300, section "B").

Test and adjustment data

Engine

Start of delivery (governor pulse) test value, ° ATDC

602.96

151

603.96

151

602.962

as of 09/89 and Basic Version Code 62/0 as of 06/91, as of Model Year 1991

140.5

603.96

Basic Version Code 62/0 as of 06/91, as of Model Year 1991

140.5

603.97 as of 09/89

140.5

Commercially available tools and testers

Designation

e. g. make, order no.

Used without adapter

Digital testers

Bosch, ETD 019.002
Sun, DIT 9100
AVL, Diesel-Tester 873

Used with adapter

Digital tester

Bosch, MOT 001.03

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

Connection diagram for available testers with adapter

017

RI generator

021

TDC pulse generator

2

Governor

2i

RI generator pin

59

TDC generator pin

001

Digital tester

010

Adapter

011

Trigger clamp

015

Test cable with connector

016

Diagnostic socket

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201
8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201
8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

Special tools

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

1 Unscrew plug (11) on the governor housing.

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

2 Screw in RI generator (017, arrow) at governor (injection pump).

8244 - Testing start of delivery using the digital tester (RIV method)          
	Engines 602.96, 603.96/97 TURBO in Models 124, 126, 140, 201

3 Screw in TDC pulse generator (021) at bracket (engine).

4 Connect digital tester as shown in connection diagram.

5 Run engine at idling speed, read off RI value (indirect start of delivery) at the digital tester at idle speed and compare with specification.

Adjust start of delivery if necessary (07.1-8300, section "B").
6 Switch off engine.

7 Disconnect digital tester.

8 Screw in plug at governor. Tightening torque 30-35 Nm.

9 Perform leaktightness check with engine running.

10 Check engine oil level, correct if necessary.