PE80.45-P-2053-60FAA | Legend of electrical function diagram for convenience opening/closing via air recirculation function | Model 204 up to model year 08/Modification Year 07 |
Code | Designation | Coordinates |
A98 | Panoramic sliding roof control module | 9K |
Code 413 | Panoramic sliding roof | 6J |
Code 414 | Electric glass tilting/sliding roof | 1J |
M10/3 | Left front door power window motor | 16K |
M10/4 | Right front door power window motor | 23E |
M10/5 | Left rear door power window motor | 21J |
M10/6 | Right rear door power window motor | 19B |
M12/5 | Panoramic sliding roof roller sun blind drive unit | 7K |
M12m1 | Tilting/sliding roof motor | 2K |
N22/7 | Automatic air conditioning control and operating unit | 12E |
N22/7s2 | Air recirculation mode button | 11B |
N69/1 | Left front door control unit | 12J |
N69/2 | Right front door control unit | 20D |
N69/3 | Left rear door control unit | 17J |
N69/4 | Right rear door control unit | 15A |
N70 | Overhead control panel control unit | 5J |
N73 | Electronic ignition switch control unit | 3D |
CAN B | Interior CAN | 6E |
1 | Circuit 15, status | |
2 | Comfort closing/opening, request | |
3 | Power window motor, request | |
4 | Power window motor, actuation | |
5 | Tilting/sliding roof motor, request | |
6 | Tilting/sliding roof motor, actuation | |
7 | Panoramic sliding sunroof motor, request | |
8 | Panoramic sliding roof roller sun blind drive unit, actuation |