PE80.20-P-2052-60FA | Legend of function schematic for electrical central locking, operation with transmitter key | Model 203.7 |
Code | Designation | Coordinates |
A2/72 | Window antenna amplifier module 2 | 10B |
A8/1 | Transmitter key | 7K |
A8/1 | Transmitter key | 13B |
A26/1 | Left front IR receiver | 13E |
M14/5 | Right front door CL [ZV] motor | 8G |
M14/6 | Left front door CL [ZV] motor | 8G |
M14/10 | Fuel filler flap CL [ZV] motor | 4B |
N10/2 | Rear SAM control unit with fuse and relay module | 6A |
N69/1 | Door control module front left | 13J |
N69/2 | Door control module front right | 13J |
N73 | EIS [EZS] control unit | 6J |
S17/3 | Left front door contact switch | 3C |
S17/4 | Right front door contact switch | 3D |
CAN B | Interior CAN | 6F |
CAN B | Interior CAN | 10K |
1 | Lock/unlock central locking, request | 7B |
1 | Lock/unlock central locking, request | 7H |
1 | Lock/unlock central locking, request | 8J |
1 | Lock/unlock central locking, request | 11B |
1 | Lock/unlock central locking, request | 14D |
1 | Lock/unlock central locking, request | 14H |
2 | Access authorization code, signal | 7H |
2 | Access authorization code, signal | 8B |
2 | Access authorization code, signal | 8J |
2 | Access authorization code, signal | 11B |
2 | Access authorization code, signal | 14D |
2 | Access authorization code, signal | 14H |
3 | Door rotary tumbler switch, status | 5C |
3 | Door rotary tumbler switch, status | 7H |
4 | Open/close central locking, request | 7D |
4 | Open/close central locking, request | 12J |
5 | CL [ZV] motor, actuation | 4A |
5 | CL [ZV] motor, actuation | 11G |