GF83.70-W-4017D | Heat exchanger, location/task/design | 27.1.98 |
MODELS 950, 952, 954
with CODE (H60) Warm air heater "Eberspächer D1 LP"
with CODE (H62) Warm air heater "Eberspächer D3 LP"
MODELS 970, 972, 974, 975, 976
with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP
with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP
MODELS 375.4, 944 with CODE (H60) Warm air heater "Eberspächer D1 LP"
W83.70-0165-06
4 Combustion air and heater blower
11 Heat exchanger
Heat exchanger location | The heat exchanger (11) is installed with its open end facing the combustion air and heater blower (4). | ||
Heat exchanger task | The heat exchanger (11) allows energy to be exchanged between the hot combustion gas in the combustion chamber and the hot air flowing around the heat exchanger insert. | ||
Heat exchanger design | The heat exchanger (11) consists of a housing with a large number of ribs on the inside and outside. The burner insert and afterburner pipe are built into the heat exchanger (11). Overheating and flame sensors are fitted to the top of the heat exchanger (11). |