GF83.70-W-4017C | Heat exchanger, location/task/design | 22.10.97 |
MODELS 970, 972, 974, 975, 976 with CODE (H61) Webasto Air Top 2000 hot air auxiliary heater
MODELS 375.4, 944, 950, 952, 953, 954 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater
MODELS 930, 932, 933, 934 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater
MODELS 930, 932, 933, 934 with CODE (H63) Auxiliary hot air heating "Webasto" Air Top 3500
W83.70-0110-06
Shown on heater "Webasto" Air Top 2000 (Code H61)
1 Heater unit
3 Combustion and heated air blower
7 Burner insert
8 Temperature limiter
9 Afterburner pipe
10 Heat exchanger
Heat exchanger, location | The heat exchanger (10) is installed on the combustion and heated air blower (3). | ||
Heat exchanger, task | The heat exchanger (10) enables energy to be exchanged between the hot combustion gases in the combustion chamber and the heated air flowing past the heat exchanger insert. | ||
Heat exchanger, design | The heat exchanger (10) consists of a housing ribbed on both the inside and outside, on the outside of which support flanges are located for the burner insert (7) with the afterburner pipe (9) and the temperature limiter (8). The inside wall of the heat exchanger (10) together with the combustion and heated air blower (3) form the combustion chamber. |