gf8370p400202a

Stationary heater/heater booster control unit, task

Typ gf · téma 83.70 · verze 0115 · 2011-10-24

Platí pro: MODEL 168 with ENGINE 668.940 with heater booster MODEL 202 with ENGINE 611.960 with heater booster MODEL 210 with heater booster MODEL 220 with ENGINE 613.960 with heater booster MODEL 220 with ENGINE 628.960 with heater booster MODEL 129 as of 1.6.97 with CODE (228) Stationary heater MODEL 203 up to 23.4.04, 210, 215, 220, 230 with CODE (228) Stationary heater MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater Webasto Tele Thermo Top S MODEL 209.3 up to 31.5.04 with CODE (2

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 129 · Řada 168 · Řada 202 · Řada 203 · Řada 209 (modely 3**) · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 463 · Řada 611 (modely 960) · Řada 613 (modely 960) · Řada 628 (modely 960) · Řada 668 (modely 940)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.11 Řídicí jednotka/relé — Řada 129 · Řada 168 · Řada 202 · Řada 203 · Řada 209 (modely 3**) · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 463 · Řada 611 (modely 960) · Řada 613 (modely 960) · Řada 628 (modely 960) · Řada 668 (modely 940)

GF83.70-P-4002-02A

Stationary heater/heater booster control unit, task

Stationary heater/heater booster control unit, task

P83.70-0257-11

The task of the STH control unit (A6n1) for models 129, 203, 209, 215, 230 or the STH or ZUH control unit (A6n1) for models 168, 202, 210, 220 or the STH and ZUH control unit (A6n1) for model 463 is to control and monitor overall heater operation:

Monitoring the signals from the glow pin unit flame monitor in its function as flame monitor and internal coolant temperature sensing,

monitoring cut-in with a starter lockout depending on internal coolant temperature sensing in the case of the heater booster,

Actuation of the combustion air blower, the circulation pump, the external fuel metering pump and the heater fan

malfunction shutoff in the event of extraordinary operating conditions such as flame discontinuation, undervoltage or overvoltage, failure of internal coolant temperature acquisition

malfunction shutoff and locking in the event of overheating.

The internal coolant temperature recording is integrated into the STH control unit (A6n1) or the STH or ZUH control unit (A6n1). In the event of a malfunction or a defect, the control unit/heat exchanger unit must be replaced.