gf8320w3121a

Climate control unit, location/function

Typ gf · téma 83.20 · verze 0101 · 2004-10-11

Platí pro: MODEL 950, 952, 953, 954 with BODY 942.899

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.20 Topení — Řada 942 (modely 899) · Řada 950 · Řada 952 · Řada 953 · Řada 954

GF83.20-W-3121A

Climate control unit, location/function

14.7.99

MODEL 950, 952, 953, 954 with BODY 942.899

Climate control unit, location/function

W83.20-0017-09

1 Operating panel

2 Heater control unit with air conditioning

3 Interior temperature sensor

4 Outside temperature sensor

5 Heat exchanger sensor

-----------------------------------------------------------------------------------------

6 Diagnosis unit

7 Heating water solenoid valve

8 Evaporator sensor

9 Refrigerant compressor with magnetic clutch

-----------------------------------------------------------------------------------------

Function

To compensate the incoming specified values from control device (1) and the incoming actual values from the interior temperature sensor (3), outside temperature sensor (4), and heat exchanger sensor (5) and to forward the corresponding pulses to the solenoid heater valve (7).

To switch the load current of the refrigerant compressor's magnetic clutch (9) as a function of the temperature of the evaporator sensor (8) (anti-icing protection).

-----------------------------------------------------------------------------------------

Activation of heater control and fresh air/recirculated air control in stationary heater mode.

Activation of blower stage 1 via digital blower regulator in stationary heater mode and when the air conditioning is switched on.

Notify the diagnosis unit (6) of problems.

-----------------------------------------------------------------------------------------