GF83.20-W-3113A | Heat exchanger sensor, location/task/function | 24.4.96 |
MODEL 950, 952, 953, 954 with BODY 942.899
W83.20-0018-08
Task | The heat exchanger sensor (1) is used together with the interior sensor to determine the existing temperature in order to reach and maintain a preselected temperature via compensation with the aid of the electronic control unit. | ||
Function | The thermal resistance decreases exponentially with increasing temperature. | ||
Location | The heat exchanger sensor (1) is located in the heater housing and is inserted from the front. The sensor is positioned using a plastic guide so that it rests perfectly above the heat exchanger. | ||
| Heat exchanger with control valve, task/location | ||
| Control unit for heater control and climate control, design/function/location | ||
| Interior temperature sensor, design//task/function/location | ||
| Outside temperature sensor, task/function/location |