Task

The heat exchanger sensor (1) is used together with the interior sensor to determine the existing temperature in order to reach and maintain a preselected temperature via compensation with the aid of the electronic control unit.

Function

The thermal resistance decreases exponentially with increasing temperature.

Location

The heat exchanger sensor (1) is located in the heater housing and is inserted from the front. The sensor is positioned using a plastic guide so that it rests perfectly above the heat exchanger.