gf7720p2000a

Convenience opening of tilting/sliding roof function

Typ gf · téma 77.20 · verze 0106 · 2001-07-13

Platí pro: MODELS 202 as of 1.6.97, 208, 210.081 /281 (except 208.4), 210 (except 210.081 /281) as of 1.3.97

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 77 Posuvné střešní okno, skládací střecha, nástavce › 77.20 Elektrické posuvné střešní okno — Řada 202 · Řada 208 (modely 3**) · Řada 210 (modely 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 081, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 281, 282, 283, 606, 610, 616, 617, 663)

GF77.20-P-2000A

Convenience opening of tilting/sliding roof function

6.12.96

MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97

Function prerequisites

no overvoltage/undervoltage

circuit 15 off and

circuit 15R off and

circuit 15C off.

Function

The overhead control panel control module (N70) receives over CAN the request for convenience opening and then actuates the tilting/sliding roof motor (M12/1). The direction in which the motor is actuated depends on whether the sliding roof or the tilting roof is open. If the tilting/sliding roof is closed, then the sliding roof is opened. The motor is actuated until the overhead control panel control module (N70) via the position measurement detects

-----------------------------------------------------------------------------------------

that the sliding or tilting roof is completely open. The convenience opening function of the tilting/sliding roof is only available in the normalized state.

Exception: if the convenience closing function of the tilting/sliding roof was interrupted by lock-up, the overhead control panel control module (N70), after the request for convenience opening, moves the tilting/sliding roof back so that the lock-up is canceled again (emergency opening).

The convenience opening function of the tilting/sliding roof is aborted if

the request over CAN is no longer received or

lock-up of the tilting/sliding roof is detected or

the function requirements listed above are no longer satisfied.

-----------------------------------------------------------------------------------------

Power tilting/sliding roof (SR [SHD]) function

GF77.20-P-0001A

Convenience closing of tilting/sliding roof (SR), function

GF77.20-P-2001A

Tilting/sliding roof (SR) normalization, function

GF77.20-P-3002A

Tilting/sliding roof (SR) position measurement, function

GF77.20-P-3001A

Convenience feature, function

GF80.45-P-0003A

Odkazované dokumenty