Battery charging procedure
1. Always leave the vent plugs in loose condition and in place during charging to avoid excess pressure due to gassing inside the battery during charging.

Y54.10-0008-01

Stationary charging function

2. Always charge the batteries in a well- ventilated area and wear eye protection and protective clothing.

Y54.10-0009-01

Stationary charging function

Warnings

A

Danger/caution

B

Shield eyes/explosive gases can cause blindness or injury

C

No Sparks/flame/smoking

D

Sulfuric acid can cause blindness or severe burns

Y54.10-0010-01

3. Always keeps sparks or flames away from the battery.

Stationary charging function

4. Check specific gravity readings, determine if further charging is still required.

Y54.10-0011-01

Stationary charging function

5. Before charge, clean the battery surface and terminals.

Y54.10-0012-01

Stationary charging function

6. Check electrolyte level, top-up if required up to the barrel level. Use only distilled water for topping up.

Y54.10-0013-01

Stationary charging function

7. Ensure that the battery charger is in OFF condition.

Y54.10-0014-01

Stationary charging function

8. To charge more than one battery, connect in series. A series connection is the one direction, in which the positive (+) of one battery is connected to the negative (-) terminal of the next battery. The voltage rating of the charger determines the number of batteries in series.

Y54.10-0015-01

Stationary charging function

9. Use proper size cables for inter connections to charger.

Y54.10-0016-01

Stationary charging function

10. Switch ON the charger.

Y54.10-0017-01

Stationary charging function

11. Charge the battery, till the top of charging voltage is reached. In the charger setting voltage shall not be less than 16.0 V per battery.

Y54.10-0018-01

Stationary charging function

12. On Obtaining the same specific gravity values consecutively, three times after intervals of twenty minutes (1 hour total duration). Switch OFF and disconnect the battery from charger.

Y54.10-0019-01

Stationary charging function

13. After satisfactory completing the charging from step 1 to 10, tighten the vent plugs.