gf4920g3034a

SCR AdBlue(R) metering valve, component description

Typ gf · téma 49.20 · verze 0100 · 2019-12-23

Platí pro: Engine 900.91/92 in model 000.001 with BlueTec Engine 902.91/93 in model 000.001 with BlueTec Engine 904.94/95/96/97 in model 000.001 with BlueTec Engine 906.93/94/95/96/98/99 in model 000.001 with BlueTec Engine 924.91/93/94 in model 000.001 with BlueTec Engine 925.9 in model 000.001 with BlueTec Engine 926.91/92/93/95/97/98 in model 000.001 with BlueTec

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 49 Výfukový systém, čistění výfukových plynů › 49.20 Dodatečná úprava výfukových plynů — Řada 000 (modely 001) · Řada 900 (modely 91*, 92*) · Řada 902 (modely 91*, 93*) · Řada 904 (modely 94*, 95*, 96*, 97*) · Řada 906 (modely 93*, 94*, 95*, 96*, 98*, 99*)

Platí také pro motory/převodovky: 924 91*, 924 93*, 924 94*, 925 9**, 926 91*, 926 92*, 926 93*, 926 95*, 926 97*, 926 98*

GF49.20-G-3034A

SCR AdBlue(R) metering valve, component description

27.11.2019

Engine

900.91/92 in model 000.001

with BlueTec

Engine

902.91/93 in model 000.001

with BlueTec

Engine

904.94/95/96/97 in model 000.001

with BlueTec

Engine

906.93/94/95/96/98/99 in model 000.001

with BlueTec

Engine

924.91/93/94 in model 000.001

with BlueTec

Engine

925.9 in model 000.001

with BlueTec

Engine

926.91/92/93/95/97/98 in model 000.001

with BlueTec

SCR AdBlue(R) metering valve, component description

W14.40-1274-08

8

AdBlue® metering device

Y109

SCR AdBlue® metering valve

Location

The SCR AdBlue® metering valve is installed in the AdBlue® metering device (8). The AdBlue® metering device (8) is located at the rear right on the cylinder head.

Task

The SCR AdBlue® metering valve makes available AdBlue® for injection at the injection nozzle.

SCR AdBlue(R) metering valve, component description

Structure

1

AdBlue® inlet

2

AdBlue® outlet

3

Electrical connector

Y109

SCR AdBlue® metering valve

G49.20-A060-02

The SCR AdBlue® metering valve is a 2/2-way valve. Inside the valve, the valve body is designed as a solenoid armature.

Function

The SCR AdBlue® metering valve is actuated by the motor control module (MR) (A6).

AdBlue® is present at the closed valve body inside the SCR AdBlue® metering valve at the operating pressure generated by the SCR AdBlue® pump (M25) . The force of a push spring keeps this valve between the AdBlue® inlet (1) and the AdBlue® outlet (2) closed.

In the case of the actuation of the SCR AdBlue® metering valve, the valve body inside the SCR AdBlue® metering valve moves and opens the opening to the AdBlue® outlet (2) so that AdBlue® can flow through.