az8370w000201b

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

Typ az · téma 83.70 · verze 0200 · 2006-09-13

Platí pro: BODY 940.899 with CODE (F04) Cab L (long) BODY 940.899 with CODE (DD5) Cab with high roof BODY 972.899 with CODE (F04) Cab L (long) BODY 972.899 with CODE (DD5) Cab with high roof

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 940 (modely 899) · Řada 972 (modely 899)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.3 Dodatečná montáž/přemontování — Řada 940 (modely 899) · Řada 972 (modely 899)

AZ83.70-W-0002-01B

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

Modification notes

14.8.06

Drill bore (4) for fuel connection from
Ø 7.5 mm to Ø 18 mm, added.

Step 6

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

W83.70-0186-01

1 Scribe the bore markings (1 and 2) as shown onto the cab floor, in the stowage compartment behind the driver seat, and make two bores with Ø 12 mm.

a 210 MM

b 55 MM

c 270 MM

Make cutouts for exhaust gas, combustion air, fuel supply and fastening

W83.70-0187-01

2 Affix flat drawing tool to the bores using the two tensioning bolts and then tighten the tensioning bolts.

3 Using the bolted on flat drawing tool make 4 bores Ø 7.5 mm (3) for the heater attachment and 1 bore Ø 7.5 mm (4) for the fuel connection at the engine tunnel.

4 Remove the flat drawing tool.

5 Drill the two bores for the tensioning bolts for the exhaust line and the combustion air intake line from Ø 12 mm to Ø 26 mm.

6 Drill bore (4) for fuel connection from Ø 7.5 mm to Ø 18 mm.

7 Deburr all holes and treat with corrosion protection.

8 Place floor covering back onto the cab floor and cut out in area of bores to match the contour of the heater flange.

To mark the surface of the cut, push through the floor covering at the fastening holes from below. Remove the preassembled flange gasket from the heater unit and use as a template.