D83.70-1206-10
1 Nut
2 Circlip
3 Bolt
4 Water heater
5 Rubber mount
6 Universal bracket for water heater
1 Install rubber mount (5) on universal bracket (6).
2 Fit universal bracket (6) to water heater (4) and secure with bolt (3).
D83.70-1207-01
3 Cut flexible exhaust gas line (7) to a length of 300 mm.
4.1 Models 901.3/4, 902.3/4, 903.3/4, 904.3/4:
Cut flexible combustion air intake line to a length of 600 mm.
4.2 Models 901.6, 902.6, 903.6, 904.6, 905.6:
Cut flexible combustion air intake line to a length of 700 mm.
Cut exhaust line to length as connection to exhaust muffler without terminal sleeve and combustion air intake line with terminal sleeve.
5 Fasten the exhaust gas line (7) with a pipe clamp and combustion air intake line (8) with a hose clamp at the exhaust connector and intake connector of the water heater.