Deployment of emergency tensioning retractor units when no deployment device is
present
Typ ar · téma 91.40 · verze 0119 · 2012-05-14
Platí pro: MODEL 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 414, 463.200 /204 /206 /207 /208 /209 /220 /221 /222 /224 /225 /227 /228 /230 /231 /232 /233 /240 /241 /243 /244 /245 /246 /247 /248 /249 /250 /254 /300 /303 /304 /306 /307 /308 /309 /320 /321 /322 /323 /324 /325 /327 /328 /330 /331 /332 /333 /336 /340 /341, 901, 902, 903, 904, 905 MODEL WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 MODEL 463.202 /236 /237 /346 up to Model Year 2013 /MOPF 201
Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.
Zařazení
Funkční skupina 3 Nástavba › 91 Sedadla, lůžka, zádržný systém › 91.40 Bezpečnostní pásy, předpínače bezpečnostních pásů — Řada 163 · Řada 168 · Řada 170 · Řada 202 · Řada 203 · Řada 208 · Řada 209 · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 414 · Řada 463 (modely 200, 202, 204, 206, 207, 208, 209, 220, 221, 222, 224, 225, 227, 228, 230, 231, 232, 233, 236, 237, 240, 241, 243, 244, 245, 246, 247, 248, 249, 250, 254, 300, 303, 304, 306, 307, 308, 309, 320, 321, 322, 323, 324, 325, 327, 328, 330, 331, 332, 333, 336, 340, 341, 346) · Řada 901 · Řada 902 · Řada 903 · Řada 904 · Řada 905
EinPAS 27 Systémy pasivní bezpečnosti/zádržné systémy › 27.17 Zádržné systémy › 27.17.20 Bezpečnostní pás/zámek bezpečnostního pásu/předepínač bezpečnostních pásů — Řada 163 · Řada 168 · Řada 170 · Řada 202 · Řada 203 · Řada 208 · Řada 209 · Řada 210 · Řada 215 · Řada 220 · Řada 230 · Řada 414 · Řada 463 (modely 200, 202, 204, 206, 207, 208, 209, 220, 221, 222, 224, 225, 227, 228, 230, 231, 232, 233, 236, 237, 240, 241, 243, 244, 245, 246, 247, 248, 249, 250, 254, 300, 303, 304, 306, 307, 308, 309, 320, 321, 322, 323, 324, 325, 327, 328, 330, 331, 332, 333, 336, 340, 341, 346) · Řada 901 · Řada 902 · Řada 903 · Řada 904 · Řada 905
AR91.40-P-0611-05A
Deployment of emergency tensioning retractor units when no deployment device is present
Danger!
Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.
Store airbag units with deployment side facing up; do not expose to temperatures above 100 °C. Interrupt the current supply when working on these units
AS91.00-Z-0001-01A
Model 163, 168, 170, 202 as of 1.7.93, 203, 208, 209, 210, 215, 220, 230, 414, 463
Danger!
Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units.
Store airbag units with deployment side facing up; do not expose to temperatures above 100 °C. Interrupt the current supply and disconnect airbag test connector/connector (AB) with emergency tensioning retractor (X11/13) when working on these units
AS91.00-Z-0001-01B
Model 202 up to 30.6.93
Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units
On model 163, 168, 170, 202, 203, 209, 208, 210, 215, 220, 230, 414, 463, not valid for
AH91.60-P-0611-02P
Ignition cable for firing airbag and seat belt tensioner units
WF58.50-P-9160-02A
Notes on disposing of airbag and emergency tensioning retractor units
All models
OS91.00-P-0001-01A
Use of self-fabricated ignition cable
1 Fabricate ignition cable with a length of 10 m with pressure switch.
2 Plug 2-pin plug coupling into the corresponding emergency tensioning retractor unit.
3 Connect ignition cable to battery.
4 Press both pressure switches at the same time.
Keep a distance of 10 m for safety.
Odkazované dokumenty
ah9160p061102p Pokyny ke kontrolovanému odpalování jednotek airbagů, bočních airbagů a
předpínačů bezpečnostních pásů
as9100z000101a Nebezpečí poranění při kontrolních a opravných pracích na jednotkách airbagu
nebo předpínače bezpečnostního pásu
as9100z000101b Nebezpečí poranění při kontrolních a opravných pracích na jednotkách airbagu
nebo předpínače bezpečnostního pásu
os9100p000101a
wf5850p916002a Zapalovací kabel k roznícení jednotek airbagu a předpínače bezpečnostního pásu