AR91.40-P-0611-02A | Ignition of removed emergency tensioning retractors | ||
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. Interrupt power supply when working on such units | |
Except model 202 up to 30.6.93 | |||
Danger! | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures above 100 °C. Interrupt the current supply and disconnect airbag test connector/connector (AB) with emergency tensioning retractor (X11/13) when working on these units | |
Model 202 up to 30.6.93 | |||
| Notes on controlled deployment of airbag, sidebag and emergency tensioning retractor units | Model 163, 164, 168, 170, 199, 202, 203, 208, 209, 210, 215, 220, 230, 240, 251, 414, 461, 463, not valid for | |
| Notes on disposing of airbag and emergency tensioning retractor units | All models |
P91.60-0219-01
2 Pressure switch, battery control
3 Pressure switch, deployment
4 Rotary switch
5 Indicator lamp, deployment
7 Plug connector, adapter cable
8 2-pin plug connector
Using the deployment device
1 Insert 2-pin plug coupling (8) at unit to be scrapped.
2 Dial the rotary switch (4) to position "1".
3 Press the battery control pressure switch (2) and deployment pressure switch (3) simultaneously.
Keep a distance of 10 m for safety.
After a successful deployment, the deployment indicator lamp (5) flashes.