AR83.70-P-1177-01A | Checking emission level with gas trace instrument | ||
Danger! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation or wear protective gloves. |
Thermo Top S heater unit test values
Number | Designation | Model 202 | Model 210 | Model 461 | Model 463 | ||
BE83.70-P-1001-03A | CO2 value in exhaust gas (diesel) | Wide open throttle operation | vol % | 9,5-12,0 | 9,5-12,0 | 9,5-12,0 | 9,5-12,0 |
BE83.70-P-1002-03A | CO2 value in exhaust gas (gasoline) | Wide open throttle operation | vol % | 9,5-12,0 | 9,5-12,0 | 9,5-12,0 | 9,5-12,0 |
Commercially available tools
Number | Designation | |
WH58.30-Z-1010-13A | CO2 test tubes, 1 to 20 percent by volume | |
WH58.30-Z-1012-13A | Gas detector | |
WH58.30-Z-1013-13A | Vehicle emissions sensor | |
WH58.30-Z-1019-13A | Hot air sensor |
P83.70-0236-01
1 Operate stationary heater or heater booster.
2 Break off both ends of the CO2 test tube.
P83.70-0237-01
3 Insert end of the CO2 test tube with the high scale value in the gas trace instrument .
4 Mount the hot air sensor or motor vehicle emission gas sensor on the other end of the CO2 test tube.
5.1 Seal the second outlet (arrow) gas-tight.
Only when the vehicle emission sensor is used.
P83.70-0238-01
6 Let heater of stationary heater or heater booster run under full load.
7 Compress the rubber bellows of the gas trace instrument by hand and keep pressed.
8 Insert the hot air sensor or motor vehicle emission sensor in the exhaust gas outlet.
P83.70-0239-01
9 Release the rubber bellows and wait until the chain (arrow) is tensioned.
10 Withdraw the gas trace instrument from the exhaust gas outlet, read off emission level and compare with the specified values.
11 Adjust CO2 level in exhaust if necessary.
12 Switch off stationary heater or heater booster.