ar8370d5653d

Remove/install fuel strainer in intake connection fittings of fuel metering pump

Typ ar · téma 83.70 · verze 0107 · 2003-09-16

Platí pro: MODEL 690.6 with CODE (H12) Hot water auxiliary heater MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Hot water auxiliary heater MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Hot water auxiliary heater MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel engine MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Hot water auxiliary heater MODE

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 690 (modely 6**) · Řada 901 (modely 0**, 3**, 4**, 6**) · Řada 902 (modely 0**, 3**, 4**, 6**) · Řada 903 (modely 0**, 3**, 4**, 6**) · Řada 904 (modely 0**, 3**, 4**, 6**) · Řada 905 (modely 6**)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.46 Čerpadlo/zásobník — Řada 690 (modely 6**) · Řada 901 (modely 0**, 3**, 4**, 6**) · Řada 902 (modely 0**, 3**, 4**, 6**) · Řada 903 (modely 0**, 3**, 4**, 6**) · Řada 904 (modely 0**, 3**, 4**, 6**) · Řada 905 (modely 6**)

AR83.70-D-5653D

Remove/install fuel strainer in intake connection fittings of fuel metering pump

18.4.97

MODEL 690.6 with CODE (H12) Hot water auxiliary heater

MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H12) Hot water auxiliary heater

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (H12) Hot water auxiliary heater

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HZ9) Heater booster, diesel engine

MODEL 901.6, 902.6, 903.6, 904.6 with CODE (HZ5) Warm air auxiliary heater 10 kW with timer

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (H12) Hot water auxiliary heater

MODEL XD1, XD2, XD3, XD4, XD5, XD6, XD7 with CODE (HZ9) Heater booster, diesel engine

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (H12) Hot water auxiliary heater

MODEL YD1, YD2, YD3, YD4, YD5, YD6, YD7 with CODE (HZ9) Heater booster, diesel engine

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (H12) Hot water auxiliary heater

MODEL WD1, WD2, WD3, WD6, WD7 with CODE (HZ9) Heater booster, diesel engine

Remove/install fuel strainer in intake connection fittings of fuel metering pump

D83.70-1274-06

1 Union nut

2 Hose clamp

3 Tank fuel line

4 Fuel strainer

Remove/Install

Danger!

Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel.

No fire, sparks, naked flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Loosen hose clamp (2)

2

Detach tank fuel line (3)

Collect fuel which flows out.

3

Unscrew union nut (1)

To release the union nut counterhold the fuel metering pump.

4

Remove the fuel strainer (4)

5

Install in the reverse order

Odkazované dokumenty