ar8370d5652c

Removing and installing fuel metering pump

Typ ar · téma 83.70 · verze 0104 · 1998-07-31

Platí pro: MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation B3L-C

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 901 (modely 06*) · Řada 902 (modely 06*, 07*) · Řada 903 (modely 06*, 07*) · Řada 904 (modely 06*)

EinPAS 39 Topení/větrání/chlazení › 39.25 Nezávislé topení/přídavné topení › 39.25.46 Čerpadlo/zásobník — Řada 901 (modely 06*) · Řada 902 (modely 06*, 07*) · Řada 903 (modely 06*, 07*) · Řada 904 (modely 06*)

AR83.70-D-5652C

Removing and installing fuel metering pump

4.11.96

MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation B3L-C

Removing and installing fuel metering pump

D83.70-0060-11

1 Electrical connector
2 Electrical connector
3 Fuel line to heater
4 Hose clamp
5 Fuel metering pump
6 Hose clamp
7 Fuel line to fuel tank
8 Washer
9 Hex. nut
10 Holder

Removal, installation

Location of fuel metering pump changed to avoid formation of vapor bubbles

If the fuel metering pump is fastened to the bottom of the heater, convert by mounting on front of heater.

BT83.70-D-0001-01A

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Loosen hose clamp (4) and pull off fuel
line (3)

Catch fuel running out.

2

Loosen hose clamp (6) and pull off fuel
line (7)

Catch fuel running out.

3

Disconnect electrical connectors (1, 2)

4

Remove fuel metering pump (5)

5

Install in opposite order

Odkazované dokumenty