ar8355p5310rg

Refrigerant compressor, remove/install

Typ ar · téma 83.55 · verze 0202 · 2019-07-16

Platí pro: Model 190

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.55 Kompresor klimatizace — Řada 190

EinPAS 39 Topení/větrání/chlazení › 39.15 Klimatizace › 39.15.40 Kompresor chladiva — Řada 190

AR83.55-P-5310RG

Refrigerant compressor, remove/install

02.07.2019

Model

190

Modification notes

04.10.2016

Safety note added

AS83.00-Z-0006-01A

28.09.2016

Safety note added

AS83.00-Z-0007-01A

28.09.2016

"Technical note" added

AH54.00-P-0001-01A

28.09.2016

General note added

AH83.30-P-0003-02A

Refrigerant compressor, remove/install

P83.55-2285-09

1

Power steering pump

6

Cable tie

2

Screw

7

Electrical connector

3

Refrigerant line

8

Bolts

4

Screw

9

Bracket

5

Refrigerant line

10

Refrigerant compressor

Warning

Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 190
except code 2U8 (Alternative refrigerant)

AS83.00-Z-0006-01A

Danger

Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 190
with code 2U8 (Alternative refrigerant)

AS83.00-Z-0007-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Topical note

Information on preventing damage to electronic components due to electrostatic discharge

AH54.00-P-0001-01A

Topical note

Notes on working in engine compartment

AH60.00-P-0042-01RG

Topical note

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Notes on handling refrigerant R1234yf

Model 190
with code 2U8 (Alternative refrigerant)

AH83.30-P-0003-02A

Notes on handling refrigerant R134a

Model 190
except code 2U8 (Alternative refrigerant)

AH83.30-N-0003-01A

Remove/install

1

Perform initial startup of refrigerant compressor (10)

When replacing the refrigerant compressor (10).

AD00.00-P-2000-04B

2

Release power steering pump (1) with connected hydraulic lines

AR46.30-P-0500RG

Removal: The hydraulic lines may not be unscrewed from the power steering pump (1).

3

Drain air conditioning system

AR83.30-P-1760RQ

4

Remove screw/bolt (2) from refrigerant compressor (10) and remove refrigerant line (3)

Compressor oils (specification 362.1)

BB00.40-P-0362-01A

Installation: The sealing ring of the refrigerant line (3) must be replaced and coated with compressor oil.

Bolt, mounting for refrigerant line to A/C compressor

*BA83.30-P-1010-01M

5

Seal openings of refrigerant line (3) and of refrigerant compressor (10) using suitable stop plugs


The openings of the refrigerant lines (3) and the refrigerant compressor (10) must be sealed.
Otherwise, penetrating dirt and moisture will damage the air conditioning system.

Record plug

*129589009100

6

Remove bolt (4) from refrigerant compressor (10) and remove refrigerant line (5)

Compressor oils (specification 362.1)

BB00.40-P-0362-01A

Installation: The sealing ring of the refrigerant line (5) must be replaced and moistened with compressor oil.

Bolt, mounting for refrigerant line to A/C compressor

*BA83.30-P-1010-01M

7

Seal openings of refrigerant line (5) and of refrigerant compressor (10) using suitable stop plugs


The openings of the refrigerant lines (3) and the refrigerant compressor (10) must be sealed.
Otherwise, penetrating dirt and moisture will damage the air conditioning system.

Record plug

*129589009100

8

Disconnect cable tie (6) and put electrical connector to one side

9

Release and disconnect electrical connection (7)

10

Remove bolt (8)

When replacing the refrigerant compressor (10).

Model 190 with engine 178.9Bolt, refrigerant compressor bracket to bracket for additional assemblies/crankcase

*BA83.55-P-1002-02A

11

Remove refrigerant compressor (10)

12

Remove bracket (9) from refrigerant compressor

When replacing the refrigerant compressor (10).

Model 190 with engine 178.9Bolt, refrigerant compressor to refrigerant compressor bracket

*BA83.55-P-1001-02A

13

Install in the reverse order

Check

14

Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak

AR83.30-P-1760RQ

Air conditioning

Number

Designation

Model 190

BA83.30-P-1010-01M

Bolt, mounting for refrigerant line to A/C compressor

Nm

20

Refrigerant compressor

Number

Designation

Engine 178

BA83.55-P-1001-02A

Bolt, refrigerant compressor to refrigerant compressor bracket

Nm

20

Refrigerant compressor

Number

Designation

Engine 178

BA83.55-P-1002-02A

Bolt, refrigerant compressor bracket to bracket for additional assemblies/crankcase

Nm

20

Refrigerant compressor, remove/install

129 589 00 91 00

Record plug

Odkazované dokumenty