P83.55-2285-09
1 | Power steering pump | 6 | Cable tie | |
2 | Screw | 7 | Electrical connector | |
3 | Refrigerant line | 8 | Bolts | |
4 | Screw | 9 | Bracket | |
5 | Refrigerant line | 10 | Refrigerant compressor |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 190 | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 190 | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on working in engine compartment | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R1234yf | Model 190 | ||
Notes on handling refrigerant R134a | Model 190 | ||
| Remove/install | ||
1 | Perform initial startup of refrigerant compressor (10) | When replacing the refrigerant compressor (10). | |
| |||
2 | Release power steering pump (1) with connected hydraulic lines | ||
Removal: The hydraulic lines may not be unscrewed from the power steering pump (1). | |||
3 | Drain air conditioning system | ||
4 | Remove screw/bolt (2) from refrigerant compressor (10) and remove refrigerant line (3) | ||
| Compressor oils (specification 362.1) | ||
Installation: The sealing ring of the refrigerant line (3) must be replaced and coated with compressor oil. | |||
Bolt, mounting for refrigerant line to A/C compressor | |||
5 | Seal openings of refrigerant line (3) and of refrigerant compressor (10) using suitable stop plugs | | |
Record plug | |||
6 | Remove bolt (4) from refrigerant compressor (10) and remove refrigerant line (5) | ||
| Compressor oils (specification 362.1) | ||
Installation: The sealing ring of the refrigerant line (5) must be replaced and moistened with compressor oil. | |||
Bolt, mounting for refrigerant line to A/C compressor | |||
7 | Seal openings of refrigerant line (5) and of refrigerant compressor (10) using suitable stop plugs | | |
Record plug | |||
8 | Disconnect cable tie (6) and put electrical connector to one side | ||
9 | Release and disconnect electrical connection (7) | ||
10 | Remove bolt (8) | When replacing the refrigerant compressor (10). | |
Model 190 with engine 178.9Bolt, refrigerant compressor bracket to bracket for additional assemblies/crankcase | |||
11 | Remove refrigerant compressor (10) | ||
12 | Remove bracket (9) from refrigerant compressor | When replacing the refrigerant compressor (10). | |
Model 190 with engine 178.9Bolt, refrigerant compressor to refrigerant compressor bracket | |||
13 | Install in the reverse order | ||
| Check | ||
14 | Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak |
129 589 00 91 00
Record plug
Odkazované dokumenty
- ad0000p200004b
- ah5400p000101a Upozornění k zamezení poškozením elektronických součástí elektrostatickým výbojem
- ah6000p004201rg Pokyny k práci v motorovém prostoru
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ah8330p000302a Pokyny pro manipulaci s chladivem R1234yf
- ar4630p0500rg
- ar8330p1760rq Vyprázdnění, odvzdušnění, nové naplnění a kontrola funkce a těsnosti klimatizace
- as8300z000601a Nebezpečí otravy při vdechnutí přehřátých výparů chladiva klimatizace naplněné chladivem R134a. Nebezpečí úrazu při kontaktu kůže a očí s tekutým chladivem R134a a při manipulaci s díly pod tlakem.
- as8300z000701a Nebezpečí požáru v důsledku vznícení chladiva R1234yf kontaktem s horkými součástmi. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí úrazu při kontaktu kůže a očí s uniklým chladivem R1234y
- bb0040p036201a Kompresorové oleje (specifikace 362.1)