AR83.50-T-5060BAS | Remove/install the air conditioning's condenser fan (roof equipment) | 10.2.03 |
MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater
MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater
MODELS NMB613.455 with CODE (HKB) Konvekta ACX 641 SAPTCO air conditioning without roof heater
T83.50-0030-11
Shown on model 613.455 with Konvekta ACX 641 SAPTCO air conditioning without roof heater code HKB
1 Condenser fan
2 Bolt
3 Electrical connector
| Remove/install | ||
Danger! | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
Danger! | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. Deburr repair panels. | |
1 | Loosen screw (2) | ||
2 | Remove condenser fan (1) and place aside | Installation: Note installation position of condenser fan (1). | |
3 | Separate cable strap | Installation: Use new tie straps. | |
4 | Separate electrical connection (3) | ||
5 | Install in the reverse order |
Odkazované dokumenty
- as0000z001701a Nebezpečí poranění řeznými ranami, resp. odřeninami u dílů vozidla s ostrými hranami
- as6500z000201a Nebezpečí ohrožení života pádem ze střechy vozidla. Nebezpečí poranění druhých osob padajícími předměty při pracích v oblasti střechy